Bosch eBike (Active/Performance/CX – Intuvia/Nyon/Kiox/Purion, classic line)

CodeMeaningComponentReliability
410One or more on-board computer buttons are blockedDisplay Per manufacturer documentation
414Connection problem with the control unitCommunication Per manufacturer documentation
418One or more buttons are permanently pressedDisplay Per manufacturer documentation
419Configuration errorFirmware Per manufacturer documentation
422Connection problem with the drive unitCommunication Per manufacturer documentation
423Connection problem with the batteryCommunication Per manufacturer documentation
424Communication error between componentsCommunication Per manufacturer documentation
426Internal time-out errorFirmware Per manufacturer documentation
430On-board computer internal battery is emptyDisplay Per manufacturer documentation
431Software version errorFirmware Per manufacturer documentation
440Internal drive-unit faultMotor Per manufacturer documentation
450Internal software errorFirmware Per manufacturer documentation
460USB port faultDisplay Per manufacturer documentation
490Internal on-board computer faultDisplay Per manufacturer documentation
500Internal drive-unit faultMotor Per manufacturer documentation
502Bicycle lighting faultLights Per manufacturer documentation
503Speed sensor faultSpeed signal Per manufacturer documentation
504Speed signal manipulation detectedSpeed signal Per manufacturer documentation
510Internal sensor errorTorque sensor Per manufacturer documentation
511Internal drive-unit faultMotor Per manufacturer documentation
530Battery faultBattery Per manufacturer documentation
531Configuration errorFirmware Per manufacturer documentation
540Temperature error (outside permitted range)Temperature Per manufacturer documentation
550Impermissible consumer detectedLights Per manufacturer documentation
580Software version errorFirmware Per manufacturer documentation
591Authentication errorFirmware Per manufacturer documentation
592Incompatible componentFirmware Per manufacturer documentation
593Configuration errorFirmware Per manufacturer documentation
595Communication errorCommunication Per manufacturer documentation
596Communication errorCommunication Per manufacturer documentation
602Internal battery fault during chargingBattery Per manufacturer documentation
603Internal battery faultBattery Per manufacturer documentation
605Battery temperature faultTemperature Per manufacturer documentation
606External battery faultBattery Per manufacturer documentation
610Battery voltage faultVoltage Per manufacturer documentation
620Charger faultCharger Per manufacturer documentation
640Internal battery faultBattery Per manufacturer documentation
655Multiple battery faultBattery Per manufacturer documentation
656Battery software version faultFirmware Per manufacturer documentation