E-Bike Doctor PRO
Bosch · Charger

620 Bosch error code 620

Charger fault

Per manufacturer documentation

Note

Bosch classic system (Intuvia/Nyon/Kiox/Purion). Smart System codes differ.

Possible causes

General, component-based causes – not a manufacturer-specific statement.

  • Faulty charger or charger cable
  • Damaged/corroded charging socket
  • BMS charge protection (temperature, cell voltage)

Safe test steps

  • Charger open-circuit output vs. its label value.
  • Does pack voltage rise while charging (measure after 5–10 min)?
  • Charging socket contacts, polarity, mechanical damage.

Workshop reference values

  • Li-ion charger final voltage: S × 4.20 V (e.g. 10S → 42.0 V); tolerance typically ±1 %.
  • Charging temperature: most Li-ion cells must not be charged below 0 °C (per datasheet).

Repair approach

  • Replace the charger with an approved one of the same voltage.
  • Replace the charging socket/cable.

Tools needed

  • Digital multimeter (CAT III, fused inputs)
  • Basic hand tools, insulated screwdrivers

Safety

  • Do not charge unattended, near flammables, or a damaged/hot pack.

This information does not replace manufacturer service documentation. Work on batteries and high-voltage parts only with the appropriate expertise.