E-Bike Doctor PRO
Displays and P-menus

SW900 LCD (King-Meter / KingMeter)

Sourced

Entering the menu

Power on: hold M for 4–5 s. Settings: hold Up and Down together for 4–5 s.

Parameters

P-no.ParameterValuesStatus
P01Backlight1 = darkest … 3 = brightestSourced
P02Distance unit0 = km, 1 = mileSourced
P03Voltage class24 V / 36 V / 48 V / 52 V – must match battery and kit voltageSourced
P04Sleep time0 = never; 1–60 minSourced
P05PAS levels0 = 3 levels, 1 = 5 levels (S830 also has a 9-level option)Sourced
P06Wheel sizein inches, 0.1 precisionSourced
P07Speed magnet count1–100 (the source's examples depend on motor type – use your motor's data)Sourced
P08Speed limit0–50 km/h; 100 = no limit (local law applies!)Sourced
P09Zero / non-zero start0 = zero start, 1 = non-zero startSourced
P10Drive mode0 = PAS only, 1 = throttle only, 2 = PAS + throttleSourced
P11PAS sensitivity1–24 (1 = most sensitive)Sourced
P12PAS start strength0–5Sourced
P13PAS magnet disc type5, 8 or 12 magnets; default 8Sourced
P15No functionNot implemented according to the sourceSourced
P16ODO resetLong-press the upper key for 5 s – note the odometer first on customer jobsSourced
P17No functionNot implemented according to the sourceSourced

For 1 parameter(s) the sources contradict each other – we do not publish those as values.

Safe workflow

  • Photograph the display label and EVERY original P-value before changing anything.
  • Record the controller model, battery nominal voltage, motor and speed-sensor type.
  • Find the manual for the exact display + controller; another model's table does not carry over.
  • Change one parameter at a time and test on a stand with the wheel raised (brake cut-off, start, every PAS level).
  • Never raise the current limit above controller/motor/battery/BMS ratings, never lower undervoltage protection, never bypass the local speed limit.

Common problems

  • Inaccurate speed: wheel size, magnet/pulse count, sensor gap and cable; identify the right P-number only from the manual.
  • No communication / code 30: protocol (e.g. S866 P20), connector pins, voltage class and display–controller compatibility. Same connector ≠ compatible.
  • Wrong battery gauge: the voltage-class parameter (e.g. SW900 P03) must match the real battery; measure with a multimeter first.
  • Delayed or intermittent PAS: magnet disc type/count (e.g. SW900 P13), sensitivity, gap and sensor orientation.