E-Bike Doctor PRO
Bafang · Current

27 Bafang error code 27

Over-current in the controller

Per manufacturer documentation

Note

Meaning may depend on model, display and firmware – verify with the manual of the exact type.

Possible causes

General, component-based causes – not a manufacturer-specific statement.

  • Over-current (short circuit, stalled motor)
  • Faulty current sensor in the controller
  • Phase short in the cable

Safe test steps

  • Free wheel rotation unpowered; phase cable damage.
  • Phase resistance symmetry without the controller.

Workshop reference values

  • No general documented measurement value – manufacturer service documentation required.

Repair approach

  • Remove the short; if it repeats, check/replace the controller.

Tools needed

  • Digital multimeter (CAT III, fused inputs)
  • Basic hand tools, insulated screwdrivers

Safety

  • Do not repeat the test if the controller heats up or smells burnt.

This information does not replace manufacturer service documentation. Work on batteries and high-voltage parts only with the appropriate expertise.